Colon Cancer Research - Causes, Treatment, Symptoms

Colon Cancer Research Today is a free monthly online journal that collates and summarizes the latest research about Colon Cancer, including details on causes, treatment, symptoms.


Colon Cancer Research Today

Home

View Latest Issue

Information About Colon Cancer

Books on Colon Cancer

Advertising in Research Today

View Other Research Today Publications



Quality assessment for CT colonography: validation of automated measurement of colonic distention and residual fluid.

Deshpande KK, Summers RM, Van Uitert RL, Franaszek M, Brown L, Dwyer AJ, Fletcher JG, Choi JR, Pickhardt PJ

Diagnostic Radiology Department, Clinical Center, National Institutes of Health, Bldg. 10, Room 1C368X, Bethesda, MD 20892-1182, USA.

OBJECTIVE: The purpose of this study was to validate automated quality assessment (QA) software for CT colonography (CTC) by comparing results obtained with the software with results of interpretation by radiologists in the assessment of colonic distention and surface area obscured by residual fluid. MATERIALS AND METHODS: CTC scans of 30 patients were selected retrospectively to span ranges of luminal distention (well distended to poorly distended) and surface area covered by residual fluid (high amount of coverage to low amount of coverage). We used QA software developed in our laboratory to automatically measure the mean distention of each of five colonic segments (ascending, transverse, descending, sigmoid, and rectum). Three experienced radiologists visually graded each scan for distention and fluid coverage. Distention and fluid scores for specific segments were assessed with Bland-Altman analysis (mean difference with 95% limits of agreement) and the weighted kappa test. Interobserver and intraobserver variability was determined with the weighted kappa test. RESULTS: For distention scoring, the mean difference between radiologists and the QA software was 0.1% (95% limits of agreement, -25.6% and 25.9%). For fluid scoring, the mean difference was -0.6% (95% limits of agreement, -8.2% and 7.1%). There was moderate to good agreement (weighted kappa value, 0.50-0.78) between the radiologists' mean scores and the scores obtained with the QA software and for interreader and intrareader assessments of distention and fluid coverage. CONCLUSION: Results with the QA software agreed with radiologists' assessment of colonic distention and residual fluid coverage but were a more objective assessment. Use of this QA software can help standardize two important factors, distention and residual fluid coverage, that affect the quality of CTC, reducing two known causes of poor CTC performance.

Published 21 November 2007 in AJR Am J Roentgenol, 189(6): 1457-63.
Full-text of this article is available online (may require subscription).

Place a permanent text-link or advertisement here for just US$15.

© 2004-2008 Colon Cancer Research Today. All Rights Reserved.



Colon Cancer Research Today Archive:

Volume 1 (2004)
  Issue 1 (November)
  Issue 2 (December)

Volume 2 (2005)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 3 (2006)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 4 (2007)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 5 (2008)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)



Colon Cancer Books

Challenges in Colorectal Cancer

Challenges in Colorectal Cancer